Delmhorst offers a wide assortment of accessories known throughout the industry for their durability.
496 contact pins are insulated except at the tips, and measure 2" overall with 1 1/8" penetration. Standard on the 26-ES, and can be used to check wood up to 5" thick.
Learn More
The 608 insulated contact pins measure 4" overall, and penetrate 3 1/4". Standard on 21-E and 18-ES electrodes, and can be used on roofing, insulation, timber, poles, and EIFS. Also available in 7” length with 6” penetration as 608/001.
Learn More
Retainer used to hold contact pins in place. Used with #496, #1849, and #A-111 pins. Available in packs of 4 as 632/4.
Learn More
An alternate to the 496 pin for the 26-ES, the 1849 is a 1 ½” insulated pin with 1/2" penetration. The 1849 is suitable for wood up to 2" thick.
Learn More
The 1985 is a replacement 30ft coaxial cable for the 1986 bale chamber sensor. Also available in 36ft and 40ft lengths as 1985/36 and 1985/40 respectively.
Learn More
Extends mounting bolts used when installing 1986 bale chamber sensor. Used for newer balers with thick chamber walls.
Learn More
Uninsulated pin and retainer with 5/16" penetration. Standard on all meters with built-in pins and the 2-E and 4-E electrodes. Used on wood up to 6/4 (1 ½”), concrete and gypsum.
Learn More
Brush used to clear off 313CUP-0005 or 313CUP-0006 sample cups.
Learn More
Retainer used to hold contact pins in place. Used with #608 and #608/001. Available in packs of 4 as 305RET-0021/4.
Learn More
This kit includes the power supply cable and mounting hardware necessary to install the FX-2000 in your tractor cab.
Learn More
This sturdy plastic carrying case fits the G-7 grain moisture meter. This case cay be ordered separately.
Learn More
This carrying case may be purchased as a part of one of our deluxe moisture meter packages, and fits all prods except the 1986 bale sensor, 830-3 prod, and 830-4 prod. Can also be purchased separately.
Learn More
Another alternative to the 496, the A-111 is an uninsulated contact pin measures 1 7/16” and has 7/16" penetration. The A-111 is compatible with both the 26-ES and the 22-E, and its tapered point makes it easier to penetrate into hard surfaces. Can be used on wood up to 2" thick.
Learn More
Plastic sleeve required when performing ASTM F-2170 tests on concrete. Used with the RH/T-S3 attachment included with Total Check and HT-4000F. Order in packs of 20 CS-3/20.
Learn More
Makes pilot holes in stucco to reduce pin damage
Learn More
Moisture content standards are great for verifying that your Delmhorst moisture meter is in calibration. The MCS-1 can be used on any meter with a wood scale. With two electrical resistance values (12% and 22%) to test your meter against, you can be sure that your readings will stand up to the strictest standards of accuracy. The MCS-1 is also available with a letter of certification traceable to NIST.
Learn More
This moisture content standard is great for verifying that your P-2000 or RDM-3P paper moisture meters are in calibration. With two electrical resistance values (6% and 10%) to test your meter against, you can be sure that your readings will stand up to the strictest standards of accuracy. The MCS-2 is also available with a letter of certification traceable to NIST.Please Note:
For P-2000 meters with serial numbers up to 19389, please order the MCS-2
For P-2000 meters with serial numbers of 19390 and above, please order the MCS-2X.
Learn More
This moisture content standard is great for verifying that your F-series hay moisture meter is in calibration. With two electrical resistance values (10% and 20%) to test your meter against, you can be sure that your readings will stand up to the strictest standards of accuracy. The MCS-5 is also available with a letter of certification traceable to NIST.
Learn More
This moisture content standard is great for verifying that your F-2000H hops moisture meter is in calibration. With two electrical resistance values (8% and 10%) to test your meter against, you can be sure that your readings will stand up to the strictest standards of accuracy. The MCS-44 is also available with a letter of certification traceable to NIST.
Learn More
This moisture content standard is great for verifying that your C-2000 cotton moisture meter is in calibration. Note that the 30-E/C long pin electrode is required to use the MCS-COTTON. With two electrical resistance values (6% and 12%) to test your meter against, you can be sure that your readings will stand up to the strictest standards of accuracy. The MCS-COTTON is also available with a letter of certification traceable to NIST.
Learn More
This moisture content standard is great for verifying that your JL-2000 leather moisture meter is in calibration. With two electrical resistance values (13% and 21%) to test your meter against, you can be sure that your readings will stand up to the strictest standards of accuracy. The MCS-JL-2000 is also available with a letter of certification traceable to NIST.
Learn More
The relative humidity test kit is great for testing the accuracy of our detachable RH/T-S1 relative humidity sensors. The air inside the test kit bottle is controlled by a salt solution, which keeps the relative humidity constant. The kit is available with either 33% or 75% relative humidity (Order asRH/TK/33 and RH/TK/75 respectively).
Learn More
Detachable relative humidity/temperature sensor that is included with Navigator Pro and HT-4000. Can be used to obtain ambient RH/T readings. Order individually or in packs of 5 as RH/T-S1/5.
Learn More
Extension cable that connects to the RH/T-S1, allowing you to easily view your meter’s screen while performing tests in hard to reach areas.
Learn More
Detachable relative humidity/temperature sensor that is included with Total Check and HT-4000F. Can be used to obtain ambient RH/T readings, or for performing ASTM F-2170 tests on concrete. Order individually or in packs of 5 as RH/T-S3/5
Learn More
The SCB-1 calibration block may be used for field calibration checks of the Proscan and Techscan moisture meters. We recommended using a 4” x 4” Styrofoam block or other non-conductive, nonmagnetic material such as plastic or fiberglass to insulate the SCB-1 from a wood or metal tabletop surface. When using the SCB-1. the meter should display 18.0, +/-1.0 on the wood scale, and 51, +/-2.0 on the Reference scale.
Learn More
Enables you to download stored readings from the meter to a PC via infrared linking. This software will enable you to:
All these features are provided in a easy to use GUI interface, and are compatible with Windows 95/98/ME/2000/XP/Vista/7/8/10.The PC/KIT is included in several of our moisture meter packages, or may be ordered separately. It can be used with the Moisture Check, Navigator Pro, RDM-3, RDM-3P, and Total Check moisture meters.
Learn More
If you need help finding the right accessories for your moisture meter, contact the experts at Delmhorst today by filling out the form.